SegAudit
Guides pages21 pages
Guides

How to choose OT firewall audit software

What to check before you buy a tool to audit the firewalls between IT and OT: offline use, vendors, traffic logs, standards, change plans and the report.

Any tool that reads a firewall configuration can tell you a rule is too broad. What you are paying for is the rest: whether anyone uses the rule, what would stop if you closed it, and how to put it back if you were wrong. That gap, between a list of broad rules and a change you can make in a Tuesday-night window, is where OT firewall audit software differs most. Where it runs, which firewalls it reads and what the report looks like are the details that follow.

This guide is the set of questions to put to any tool, in the order buyers usually rule tools out. Offline comes first because a no there ends the conversation.

1. Does it run offline?

The configuration and traffic log of an OT firewall are a map of how to reach the controllers. Many asset owners will not let either leave the site, and many jump hosts in the industrial DMZ have no route out. A tool that phones home for a license check, or sends the config to a hosted model for analysis, fails the evaluation before anyone has read a finding.

Check that it:

  • Runs on a workstation or a jump host with no internet connection, including the license check and updates.
  • Sends no part of the analysis to a hosted service or a cloud model.
  • Reads exported files rather than needing a credential on the firewall.
  • Can be verified on a connected machine before it is carried in: a signature on each release and a software bill of materials (SBOM).

The air-gapped firewall audit guide covers the carry-in, carry-out routine.

2. Which firewalls does it read?

Make the list before the demo: every firewall and router on a boundary into OT, including the one at the small site that an integrator installed years ago and nobody has logged in to since. Then check each entry against the vendor’s support list, and ask which entries were tested on a real device and which were read from documentation.

For each boundary device, check:

  • The vendor and the operating system versions, for example PAN⁠-⁠OS and Panorama, FortiOS, Cisco ASA, Cisco FTD with FMC, Check Point, Juniper SRX.
  • Whether it reads the manager’s export (Panorama, FMC, a Check Point management server) or only single firewalls.
  • Whether it reads routers and Layer 3 switches whose access lists separate zones.
  • Which versions were lab-tested and which were read from documentation only.

A tool that reads half your boundaries leaves the other half to a spreadsheet, which is where the audit was before you bought anything.

3. Does it use traffic logs?

A rulebase shows what could connect. A traffic log shows what did. The two answer different questions, and a tool that blends them will have you arguing with the controls engineer about a rule nobody has used in a year.

  • What the rules allow comes from the configuration alone. It is the exposure, whether or not anyone uses it today.
  • What the traffic shows comes from the firewall’s session log over a window. It tells you which paths carry production traffic, which rules are unused, and which broad allows are the dangerous kind: live.

Ask whether each finding says which of the two it rests on, and how long a log window the tool expects. A week shows what is in use. Before retiring a rule that looks unused, 30 days or more is safer, so month-end jobs and vendor visits show up. In the Northline sample that ships with SegAudit, a made-up three-site company, 66 allow rules touch OT. Read with its traffic log, the review sends 12 back to their owners to recertify, removes 2, retires 30 through the change package and keeps 22. Without the log, it could not tell a quiet rule from a dead one.

The Security policy screen in the Northline sample: rule review of 66 allow rules that touch OT, with 12 to recertify, 2 to remove, 30 retired by the change package and 22 to keep, and rule hygiene with 3 shadowed, 18 redundant and 3 consolidation findings

4. Does it keep live control and safety paths?

Closing every broad rule is easy. Closing them without stopping a line is the job. A tool that does not know industrial protocols can report Modbus from an HMI to its controller as a finding and propose to cut it; that is the process working.

Check that the tool:

  • Knows which flows are industrial protocols, and which hosts depend on them.
  • Keeps a live control or safety path as a narrow exception instead of dropping the broad rule that carries it.
  • Warns when a proposed change would cut a production host.
  • Leaves same-cell control traffic alone, and between cells inside OT proposes logging before it proposes a block.

5. Which standards does it map findings to?

Look for a tool that maps findings to the standards you answer to, such as IEC 62443-3-3, NIST SP 800-82r3, NIST CSF 2.0 or NERC CIP, and says which controls the firewall evidence supports, only partly supports, or leaves as a gap.

Be wary of a tool that claims to prove compliance, assigns an achieved security level, or prints a compliance score from a firewall export. A rulebase is evidence for the segmentation controls, not for the whole standard, and the target security level comes from the asset owner’s own risk assessment. The Purdue model is a common reference for placing zones on levels; NIST SP 800-82r3 treats it as one of several models, not a requirement.

The IEC 62443 zones and conduits and NIST SP 800-82r3 guides explain what each standard asks of a firewall.

6. Does it write the changes, with a rollback?

A finding is an opinion until someone writes the change. Ask who that someone is. If the answer is your firewall engineer, with a PDF of findings and a blank change ticket, the tool has handed back the hard part.

Check whether it:

  • Writes each change in the firewall’s own commands or web steps, for the platforms you run.
  • Gives each change a pre-check, a verification step and a rollback, written before the window.
  • Orders changes into windows, so the safest go first.
  • Leaves the change to your team and your change process, rather than pushing it to the firewall.
  • Shows, from the next traffic log, whether each change took effect and whether anything production needed was cut.

The OT firewall change plan guide shows what a complete change plan holds.

7. What does the report look like?

Ask for a sample before the trial, and read it the way the site manager will. Check that:

  • Each finding names the rule, and with a log, the sessions and hosts behind it.
  • The scope notes say what the evidence could not see, such as a short log window or rules that do not log.
  • There is a short brief for site managers and a detailed report for engineers.
  • A consultant can put their firm’s name on it, if you deliver assessments to clients.
  • It carries the SHA-256 of the files it was built from, so a reader can tie it to the evidence.

The proving OT segmentation guide covers what an auditor or insurer looks for in it.

8. How is it bought and run?

  • Is it licensed per firewall, per site, per user or per engagement, and does that fit how many boundaries you have?
  • Can you try it on your own files without a sales call?
  • Who runs it day to day: a firewall engineer, an OT security lead, or an outside consultant?

How SegAudit answers these

SegAudit runs offline, as a desktop install or one signed container on a jump host, and reads exported files from Palo Alto Networks, Fortinet, Cisco, Check Point and Juniper firewalls and Cisco IOS routers; the firewall support page lists versions and which were lab-tested. With a traffic log, it keeps what the rules allow apart from what the traffic shows. It maps findings to IEC 62443-3-3, NIST CSF 2.0 and other frameworks as supported, partial or gap, and writes ordered change windows with pre-checks and a rollback for each change, in the firewall’s own commands (for Juniper SRX and Cisco IOS routers, in words for now). Your team applies them. The sample deliverable shows the brief and report from the synthetic Northline sample.

Common questions

What is OT firewall audit software?

Software that reads the rules on the firewalls between IT and OT, and ideally their traffic logs, and reports which paths into the control network the rules allow and which are in use. Most also review each rule and propose changes. The good ones write the rollback too.

Can a general firewall audit tool review OT firewalls?

It can read the rules. Before you rely on it, check that it knows industrial protocols, places zones on levels such as the Purdue model, and keeps live control and safety paths when it proposes changes. A tool written for office networks may recommend closing a path the process needs.

Do I need a traffic log to audit an OT firewall?

No, but without one every finding is a path the rules allow, not one known to be in use. A log of a week or more shows which paths carry traffic and which rules are unused, and it is what lets the review retire a rule with evidence rather than a guess.

Can audit software prove IEC 62443 compliance?

No. Firewall evidence supports the segmentation and data flow requirements, such as the restricted data flow theme in IEC 62443-3-3. Achieved security levels and certification need an assessment of the whole system.

Run the free Quick checkSee a sample deliverable